Author |
Message |
Iceman117
New member Username: Iceman117
Post Number: 1 Registered: 4-2007
| Posted on Wednesday, April 18, 2007 - 11:17 pm: |
|
i have a connex 3300 hp that has lost some of its modulation but only on the low power setting, it still works good on hi power. just wondering if anyone has any ideas on what to look for, thanks in advance for any assistance |
Chronic
Junior Member Username: Chronic
Post Number: 41 Registered: 10-2006
| Posted on Friday, April 20, 2007 - 9:30 pm: |
|
I'd say start with looking at your meter you are using to check modulation. I personally would think that if you have it on a higher deadkey then you should have it on a lower key as well. But I guess I could be wrong. You could start shot-gunning parts if you feel like it. If not the best bet would be to use a scope and look for a bad/weak transistor in the modulation chain. You should always have more out than what is coming in. What kinda meter are you using? |
Iceman117
New member Username: Iceman117
Post Number: 2 Registered: 4-2007
| Posted on Tuesday, April 24, 2007 - 11:16 pm: |
|
thanks for the reply, i was checking it with a dosy 2000 meter, i ended up fiddiling with vr 12 and found that it wasnt making good connection, fixed that and everything went right back to normal |