Author |
Message |
Wildrat
Intermediate Member Username: Wildrat
Post Number: 320 Registered: 12-2003
| Posted on Thursday, November 17, 2005 - 6:09 pm: |
|
On the tower should I ground each section to each other? Should I also ground the tower right at the base? I was going to run a ground wire from the antenna base to the tower base and ground it there,or is it enough that the I-Max base is attatched to the tower by the mounting hardware (U Bolts)? My coax is going to the other end of the house for entry, this is where I am going to mount the polyphaser and ground it for entry into the house, is this right? Wildrat CEF674 |
Starface
Intermediate Member Username: Starface
Post Number: 322 Registered: 1-2005
| Posted on Thursday, November 17, 2005 - 7:01 pm: |
|
I run a wire from the base of the Imax down to the ground rod and a mast clamp on the base of one tower leg with a wire running off it to the ground rod too.. entry point of the house is where the polyphaser/s should go and grounded to another ground rod... If you need Ground Rods I have a few you can have. Till next time Starface CEF#476 Southeast Net Control Auburndale,FL |
Wildrat
Intermediate Member Username: Wildrat
Post Number: 321 Registered: 12-2003
| Posted on Thursday, November 17, 2005 - 7:14 pm: |
|
I've got four already, plus the ones that are in the ground already. Wildrat |