Copper Talk » Ask The Tech » Amplifiers » KL-203 « Previous Next »

Author Message
Top of pagePrevious messageNext messageBottom of page Link to this message

Carls86fiero
Junior Member
Username: Carls86fiero

Post Number: 46
Registered: 3-2005
Posted on Thursday, June 02, 2005 - 5:08 pm:   Edit Post Delete Post    Move Post (Moderator/Admin Only)

This has been the longest 2 1/2 weeks of my life. got the KL-203 today. run all the power wires from the battery, hooked up the Amp and wahla....it doesn't work right. some relay inside keeps hanging up. it does not want to go back to recieve mode. let it sit there for awhile and then it will recieve. go to transmitting and it works a few mins, then back to hanging up..
Top of pagePrevious messageNext messageBottom of page Link to this message

Tech808
Moderator
Username: Tech808

Post Number: 5942
Registered: 8-2002


Posted on Thursday, June 02, 2005 - 7:29 pm:   Edit Post Delete Post    Move Post (Moderator/Admin Only)

Carls86fiero,

What kind of radio are you using it with and what is your Dead Key Power set at?

Have you checked to make sure the Jumper you are using is Good?

How long is the Jumper you are using?

Did you pruchase it from Copper?

The more information you can give us on your set up the better chance we have of trying to help.


Lon
Tech808
CEF808
N9OSN
Top of pagePrevious messageNext messageBottom of page Link to this message

Carls86fiero
Junior Member
Username: Carls86fiero

Post Number: 47
Registered: 3-2005
Posted on Thursday, June 02, 2005 - 9:37 pm:   Edit Post Delete Post    Move Post (Moderator/Admin Only)

magnum 257
Dead key 3-4 watts am
6-8 watts SSB
2 ft patch cable

amp was through copper
Top of pagePrevious messageNext messageBottom of page Link to this message

Carls86fiero
Junior Member
Username: Carls86fiero

Post Number: 48
Registered: 3-2005
Posted on Thursday, June 02, 2005 - 9:41 pm:   Edit Post Delete Post    Move Post (Moderator/Admin Only)

Oh and another thing is when i key up you can hear the relay come on, but when you unkey the amp stays on. if i key it several times quickly it will release and go back into recieve mode. on both am and sideband.
Top of pagePrevious messageNext messageBottom of page Link to this message

Chad
Intermediate Member
Username: Chad

Post Number: 303
Registered: 11-2004


Posted on Friday, June 03, 2005 - 9:54 am:   Edit Post Delete Post    Move Post (Moderator/Admin Only)

Check your grounding, There could be an oscillation causing the amp to think it's seeing input thus holding the TX relay closed, it's a common problem I hear
Top of pagePrevious messageNext messageBottom of page Link to this message

Crackerjack
Advanced Member
Username: Crackerjack

Post Number: 596
Registered: 7-2004
Posted on Friday, June 03, 2005 - 2:16 pm:   Edit Post Delete Post    Move Post (Moderator/Admin Only)

Your jumper is toooo short. Already been through this one with my 257.

The Copper tech told me 9 foot from radio to the amp, and it has worked since.

It is something to do with an impedance mismatch -that is more criticall with come radios more than others, 9 feet,
Top of pagePrevious messageNext messageBottom of page Link to this message

1861
Intermediate Member
Username: 1861

Post Number: 223
Registered: 2-2004


Posted on Friday, June 03, 2005 - 6:36 pm:   Edit Post Delete Post    Move Post (Moderator/Admin Only)

Had to take my dk all way down to 1 for My KL 203 . Works great there
Top of pagePrevious messageNext messageBottom of page Link to this message

Crackerjack
Advanced Member
Username: Crackerjack

Post Number: 600
Registered: 7-2004
Posted on Friday, June 03, 2005 - 7:30 pm:   Edit Post Delete Post    Move Post (Moderator/Admin Only)

Lon tuned my M-257 minimum output down to about 1/3 watt, that is where I turn it for operation with my amp.

2 watt works, but I get better reports from the 1/3 - 1/2 watt output.