Copper Talk » Ask The Tech » General Technical Questions » Archived Messages » HOW DO I CHECK AMP. PILLS « Previous Next »

Author Message
Top of pagePrevious messageNext messageBottom of page Link to this message

Johnhenre
Junior Member
Username: Johnhenre

Post Number: 48
Registered: 1-2004
Posted on Saturday, October 02, 2004 - 6:46 am:   Edit Post Delete Post    Move Post (Moderator/Admin Only)

I NEED THE PROPER WAY TO CHECK A SD 1446 AND A 2SC2879 PILL USEING IF POSSIBLE A OHM METER? BOB
Top of pagePrevious messageNext messageBottom of page Link to this message

Bruce
Senior Member
Username: Bruce

Post Number: 1640
Registered: 9-2003
Posted on Saturday, October 02, 2004 - 9:38 am:   Edit Post Delete Post    Move Post (Moderator/Admin Only)

connect meter to base and measure the junction by red probe ( + ) to collector then emitter then reverse the probes put black probe ( - ) on base and measure c and e again. THEN measure collector to emitter the same way. NOW this will only tell you the devise in not FRIED or open but 90% of the time if it shows good this way it probley is.
Top of pagePrevious messageNext messageBottom of page Link to this message

Therealporkchop
Member
Username: Therealporkchop

Post Number: 60
Registered: 11-2002
Posted on Monday, October 04, 2004 - 6:58 pm:   Edit Post Delete Post    Move Post (Moderator/Admin Only)

I bought one of those cheap Rat Shack transistor checkers. It works ok, I guess. You might wanna try that?