Author |
Message |
Anonymous
| Posted on Tuesday, August 21, 2001 - 4:03 pm: |
|
I read on this page that the Boomer 600 can be used on ssb. Since there does not seem to be a ssb switch on the front of the amp , does this mean there is automatic ssb, with a delay on am ? Thanx |
307 (307)
| Posted on Wednesday, August 22, 2001 - 6:51 pm: |
|
It is called "Automatic" , however I have never had success with it working that way. The fastest way to correct the problem is to put about a 450 uF , 35 Volt electryolitic capacitor across the TX relay coil. The driver for the relay is capable of charging it up fast enough so you will not notice a difference until you unkey , you will see about a 2 second delay while the cap discharges. This is a crude way but works fine...There already is a diode across the relay to remove reverse current so that it will not hurt the TX transistor. |
Anonymous
| Posted on Thursday, August 23, 2001 - 12:52 pm: |
|
Thanx! Now thats helpful info. Now if I can get my Klv 550 running I will be in great shape. No one seems to know if I can bypass the 6 position power selector (wich is bad) anyway Thanx again. |
Anonymous
| Posted on Thursday, August 23, 2001 - 9:04 pm: |
|
HELP 307 I HAVE A KLV 350 AND EVERYTHING ELSE I HAVE IS NEW THE BEST YOU CAN BY I HAVE TRIED EVERY SIZE OF JUMPER BETWEEN MY RADIO AND AMP AND AMP AND METER HERES WHAT HAPPENS MY SWR IS 1 WHEN I KEY UP WHEN I TALK IT GOES UP YO 3,THANK YOU I HOPE YOU CAN HELP ME |
|