Does anybody have the settings for a Sencor Mighty-Mite TC 109 Tube Tester to check some 8950 tubes???? This tester is older than the 8950 tube make,... so I am trying to find the right calibration/voltage for the tester.
Thanks XLAXX
Top of pagePrevious messageNext messageBottom of page Link to this message

Scrapiron63
Posted on Thursday, May 09, 2002 - 5:26 pm:   Edit Post Delete Post    Move Post (Moderator/Admin Only)

I have a Sencore TC 162, Mighty Mite VII, this is the setup for 8950 with it.
Pins, 1-6-7-8-0
Filament, "B"--13
Load, "C"-- A
Setup, "D"---5
Tube socket--10

If your book has the 6KV6, the 8950 will setup the same except for the voltage, 12 instead of 6, and pin 9 does not need to be on for the 8950.
Top of pagePrevious messageNext messageBottom of page Link to this message

xlaxx
Posted on Friday, May 10, 2002 - 11:46 am:   Edit Post Delete Post    Move Post (Moderator/Admin Only)

Scrap-
I'll try it and see if it works. I'll get back with ya.... thanks!
xlaxx
Top of pagePrevious messageNext messageBottom of page Link to this message

xlaxx
Posted on Thursday, May 16, 2002 - 12:03 pm:   Edit Post Delete Post    Move Post (Moderator/Admin Only)

scrap-
the settings worked for the sencor t109! thanks! unfortunately, the tubes were only 50-60%.... bummer! still looking for 8950 tubes... the saga continues and the siltronix amp continues to sit gathering dust.... ain't life grand?! oh ya....